1. It is strictly forbidden to start the laser power supply and Q-switching power supply when there is no water or the water cycle is abnormal;
2. The Q power supply is not allowed to work without load (that is, the output terminal of the Q-modulated power supply is suspended);
3. If there is an abnormal phenomenon, first turn off the vibrating mirror switch and the key switch, and then check;
4. It is not allowed to start other components before the krypton lamp is ignited to prevent high voltage from entering and damaging the components;
5. Note that the output terminal (anode) of the laser power supply is suspended in the air to prevent ignition and breakdown with other electrical appliances;
6. Keep the inner circulating water clean. Clean the water tank regularly and replace it with clean deionized water or pure water.